LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

> Back to components

Construction assembly A0585

Lignum ID-№
A0585
Catalog number
A.2.04.M9
Source of construction assembly
Lignum, Year 2016
Base structure
Hollow box element
Paneling
Substructure with rubber-mounted hangers
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 433
Construction height
585 mm
Weight
301 kg/m2
U-value
≈ 0.219 W/m2K
GWP
58.46 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of hollow box element, without sheathing, double ceiling covering. Substructure mounted with flexible hangers with cavity insulation with air flow resistivity [r] of 5≤ r ≤50 kPa s/m², without dampening in the supporting structure, with cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with anhydrite screed.
Values of airborne sound insulation
Rw 78 dB
C -5 dB
C50-3150 -16 dB
Values of footfall sound insulation
Ln,w 37 dB
CI 2 dB
CI50-2500 15 dB

Graphic

On-lying material: Anhydrite
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Rigid, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation as between-rafter insulation
Bond: Rigid, execution of the prior art.
Lower skin layer 1: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa*s/m²
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Smoothed joints

Assembly

Comment Cavity damping reduces cavity resonances. The relevant parameter is not bulk density but airflow resistivity (5–50 kPa·s/m²). The insulation material must fill at least 70% of the cavity height and 80% of the cavity width. See Lignum publication «Schallschutz im Holzbau», Section 4.5.

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Anhydrite Generic product 110 kg/m2 - - 04.005 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Sager, Swisspor, Zisola, Isover 2.4 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Cement panels, glued on sub-floor Generic product 120 kg/m2 - - 02.007 91.136
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Stora Enso, Swiss Krono Group, Pfleiderer, Binderholz, Novatop, Pius Schuler, Schilliger Holz 11.8 kg/m2 - - 07.001 91.048
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Label swiss wood, Generic product, Schilliger Holz 15.1 kg/m2 07.003.01 91.047
Cavity dampening Fiber insulation as between-rafter insulation Flumroc, Gutex, Sager, Swisspor, Isover, Schilliger Holz 4.5 kg/m2 - - 10.008 91.173
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Stora Enso, Swiss Krono Group, Pfleiderer, Binderholz, Novatop, Pius Schuler, Schilliger Holz 11.8 kg/m2 - - 07.001 91.048
Coupling Rubber mounted direct hanger b=60mm Protektor, Knauf, Rigips, Fermacell, Ampack - - - -
Battens / profiles CD-ceiling profile b=60mm Protektor, Knauf, Rigips, Fermacell 1.1 kg/m2 06.011 91.143
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa*s/m² Flumroc, Gutex, Sager, Swisspor, Isofloc, Isover, Schilliger Holz 2.6 kg/m2 - - 10.008 91.173
Ceiling covering 1st layer Plasterboard type A Knauf, Rigips 11 kg/m2 - - 03.008 91.064
Ceiling covering layer 2 Plasterboard type A Knauf, Rigips 11 kg/m2 - - 03.008 91.064
Surface / treatment Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
119314
UBP'21/m2
A1-A3 + C1-C4
 
┣
Environmental impact points from production (UBP_pro)
103939
UBP'21/m2
A1-A3
 
┗
Environmental impact points from disposal (UBP_dis)
15421
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
676.93
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy from production (PE_pro)
657.43
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy production, energetically consumed (PE_E_pro)
457.11
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy production, materially bound (PE_M_pro)
202.44
kWh oil-eq/m2
A1-A3
 
┗
Primary energy from disposal (PE_dis)
19.52
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
459.43
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Renewable primary energy from production (PE_RT_pro)
458.59
kWh oil-eq/m2
A1-A3
 
┃
┣
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
264.32
kWh oil-eq/m2
A1-A3
 
┃
┗
Renewable primary energy from production, materially bound (PE_RM_pro)
193.09
kWh oil-eq/m2
A1-A3
 
┗
Renewable primary energy from disposal (PE_RT_dis)
0.94
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
219.34
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy not renewable from manufacturing (PE_NRT_pro)
200.83
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
191.64
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.19
kWh oil-eq/m2
A1-A3
 
┗
Primary energy not renewable from disposal (PE_NRT_dis)
18.59
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
58.46
kg CO2/m2
A1-A3 + C1-C4
 
┣
Greenhouse gas emissions from manufacturing (GWP_pro)
52.66
kg CO2/m2
A1-A3
 
┗
Greenhouse gas emissions from waste disposal (GWP_dis)
5.92
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
63.44
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
17.30
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)